0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TEN 20-2411WIN

TEN 20-2411WIN

  • 厂商:

    TRACOPOWER

  • 封装:

    -

  • 描述:

    TEN 20-2411WIN

  • 数据手册
  • 价格&库存
TEN 20-2411WIN 数据手册
DC/DC Converter TEN 20WIN Series, 20 Watt • • • 2" x 1" x 0.4" metal package • • • • I/O isolation 1500 VDC Ultra wide 4:1 input range Operating temperature range -40°C to +85°C Input filter to meet EN 55022 class A Adjustable output voltage UL 62368-1 IEC 62368-1 The TEN 20WIN series is a family of high performance 20W DC/DC converter modules featuring ultra wide 4:1 input voltage ranges in a ultra compact 2“ x 1“ low profile package with industry-standard footprint. A very high efficiency allows an operating temperature range of –40°C to 85°C. Further standard features include remote On/Off, output voltage trimming, over voltage protection and short circuit protection. Typical applications for these converters are battery operated equipment and distributed power architectures in communication and industrial electronics, everywhere where isolated, tightly regulated voltages are required. Remote On/Off Models Order Code Input Voltage Range TEN 20-2410WIN TEN 20-2411WIN TEN 20-2412WIN TEN 20-2413WIN TEN 20-2421WIN TEN 20-2422WIN TEN 20-2423WIN TEN 20-4810WIN TEN 20-4811WIN TEN 20-4812WIN TEN 20-4813WIN TEN 20-4821WIN TEN 20-4822WIN TEN 20-4823WIN 9 - 36 VDC (24 VDC nom.) 18 - 75 VDC (48 VDC nom.) Output 1 Output 2 Vnom Imax 3.3 VDC 5 VDC 12 VDC 15 VDC +5 VDC +12 VDC +15 VDC 3.3 VDC 5 VDC 12 VDC 15 VDC +5 VDC +12 VDC +15 VDC 5'500 mA 4'000 mA 1'670 mA 1'330 mA 2'000 mA 833 mA 667 mA 5'500 mA 4'000 mA 1'670 mA 1'330 mA 2'000 mA 833 mA 667 mA Vnom Efficiency Imax –5 VDC –12 VDC –15 VDC 2'000 mA 833 mA 667 mA –5 VDC –12 VDC –15 VDC 2'000 mA 833 mA 667 mA typ. 85 % 88 % 86 % 86 % 88 % 87 % 87 % 85 % 88 % 87 % 87 % 89 % 88 % 88 % Options TEN-HS1 - Optional Heat Sink with Height = 0.22 inch: www.tracopower.com/products/ten-hs1.pdf www.tracopower.com November 30, 2022 Page 1 / 5 TEN 20WIN Series, 20 Watt Input Specifications Input Current 24 Vin models: 50 mA typ. (3.3 Vout model) 65 mA typ. (5 Vout model) 22 mA typ. (12 Vout model) 22 mA typ. (15 Vout model) 55 mA typ. (5 / -5 Vout model) 30 mA typ. (12 / -12 Vout model) 30 mA typ. (15 / -15 Vout model) 48 Vin models: 35 mA typ. (3.3 Vout model) 35 mA typ. (5 Vout model) 15 mA typ. (12 Vout model) 15 mA typ. (15 Vout model) 35 mA typ. (5 / -5 Vout model) 17 mA typ. (12 / -12 Vout model) 17 mA typ. (15 / -15 Vout model) 24 Vin models: 2'750 mA max. 48 Vin models: 2'750 mA max. 24 Vin models: 50 VDC max. (100 ms max.) 48 Vin models: 100 VDC max. (100 ms max.) 24 Vin models: 7 VDC min. / 8 VDC typ. / 8.8 VDC max. 48 Vin models: 14.5 VDC min. / 16 VDC typ. / 17.5 VDC max. 20 mA typ. - At no load - At full load Surge Voltage Under Voltage Lockout Reflected Ripple Current Recommended Input Fuse 24 Vin models: 4'000 mA (slow blow) 48 Vin models: 2'000 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Internal Pi-Type Input Filter Output Specifications Output Voltage Adjustment Voltage Set Accuracy Regulation - Input Variation (Vmin - Vmax) - Load Variation (0 - 100%) Ripple and Noise (20 MHz Bandwidth) - Cross Regulation (25% / 100% asym. load) - single output - dual output Capacitive Load - single output - dual output ±10% (By external trim resistor) See application note: www.tracopower.com/overview/ten20win Output power must not exceed rated power! ±1% max. single output models: 0.2% max. dual output models: 0.5% max. single output models: 0.5% max. dual output models: 1% max. (Output 1) 1% max. (Output 2) dual output models: 5% max. 3.3 Vout models: 5 Vout models: 12 Vout models: 15 Vout models: 5 / -5 Vout models: 12 / -12 Vout models: 15 / -15 Vout models: 3.3 Vout models: 5 Vout models: 12 Vout models: 15 Vout models: 5 / -5 Vout models: 12 / -12 Vout models: 15 / -15 Vout models: Minimum Load Temperature Coefficient 60 mVp-p typ. (w/ 0.1 µF, 50 V MLCC) 75 mVp-p typ. (w/ 0.1 µF, 50 V MLCC) 75 mVp-p typ. (w/ 0.1 µF, 50 V MLCC) 75 mVp-p typ. (w/ 0.1 µF, 50 V MLCC) 100 / 100 mVp-p typ. (w/ 0.1 µF, 50 V MLCC) 100 / 100 mVp-p typ. (w/ 0.1 µF, 50 V MLCC) 100 / 100 mVp-p typ. (w/ 0.1 µF, 50 V MLCC) 18'000 µF max. 9'600 µF max. 1'650 µF max. 1'050 µF max. 4'800 / 4'800 µF max. 825 / 825 µF max. 525 / 525 µF max. Not required ±0.02 %/K max. All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 2 / 5 TEN 20WIN Series, 20 Watt Start-up Time Short Circuit Protection Overload Protection Output Current Limitation 20 ms typ. / 60 ms max. Continuous, Automatic recovery Indefinite Mode 125 - 170% of Iout max. 150% typ. of Iout max. 122% typ. of Vout nom. (depending on model) 3.9 VDC (3.3 VDC model) 6.2 VDC (5 / ±5 VDC model) 15 VDC (12 / ±12 VDC model) 18 VDC (15 / ±15 VDC model) 220 mV max. (25% Load Step) 250 µs typ. (25% Load Step) Overvoltage Protection Transient Response - Peak Variation - Response Time Safety Specifications Safety Standards EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 www.tracopower.com/overview/ten20win PD 2 Not mains connected - IT / Multimedia Equipment - Certification Documents Pollution Degree Over Voltage Category EMC Specifications EMI Emissions - Conducted Emissions - Radiated Emissions External filter proposal: EMS Immunity - Electrostatic Discharge Air: Contact: - RF Electromagnetic Field - EFT (Burst) / Surge Ext. input component: - Conducted RF Disturbances - PF Magnetic Field Continuous: 1 s: EN 61204-3 (Low Voltage Power Supplies) EN 55032 class A (with external filter) EN 55032 class B (with external filter) EN 55032 class A (with external filter) EN 55032 class B (with external filter) www.tracopower.com/overview/ten20win EN 61204-3 (Low Voltage Power Supplies) EN 61000-4-2, ±8 kV, perf. criteria B EN 61000-4-2, ±6 kV, perf. criteria B EN 61000-4-3, 10 V/m, perf. criteria A EN 61000-4-4, ±2 kV, perf. criteria B EN 61000-4-5, ±1 kV, perf. criteria A KY 220 µF / 100 V EN 61000-4-6, 10 Vrms, perf. criteria A EN 61000-4-8, 100 A/m, perf. criteria A EN 61000-4-8, 1000 A/m, perf. criteria A General Specifications Relative Humidity Temperature Ranges Power Derating Cooling System - Operating Temperature - Case Temperature - Storage Temperature - High Temperature 95% max. (non condensing) –40°C to +85°C +105°C max. –55°C to +125°C Depending on model Depending on model (with Heat Sink) See application note: www.tracopower.com/overview/ten20win Natural convection (20 LFM) All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 3 / 5 TEN 20WIN Series, 20 Watt Remote Control - Voltage Controlled Remote - Off Idle Input Current - Remote Pin Input Current Altitude During Operation Switching Frequency Insulation System Isolation Test Voltage Isolation Resistance Isolation Capacitance Reliability Washing Process - Input to Output, 60 s - Input to Case, 60 s - Output to Case, 60 s - Input to Output, 500 VDC - Input to Output, 100 kHz, 1 V - Calculated MTBF See Cleaning Guideline: Environment - Vibration - Mechanical Shock - Thermal Shock Housing Material Base Material Potting Material Pin Material Pin Foundation Plating Pin Surface Plating Housing Type Mounting Type Connection Type Footprint Type Soldering Profile Weight Thermal Impedance On: 3.0 to 12 VDC or open circuit Off: 0 to 1.2 VDC or short circuit Refers to 'Remote' and '-Vin' Pin 2.5 mA typ. -0.5 to 0.5 mA 5'000 m max. 360 - 440 kHz (PWM) 400 kHz typ. (PWM) Functional Insulation 1'600 VDC 1'600 VDC 1'600 VDC 1'000 MΩ min. 1'500 pF max. 1'800'000 h (MIL-HDBK-217F, ground benign) Allowed (hermetical product) www.tracopower.com/info/cleaning.pdf MIL-STD-810F 7.7 g, 3 axis, random waveform, 60 min MIL-STD-810F 40 g, 3 axis, terminal peak sawtooth, 11 ms MIL-STD-810F -55°C to +125°C, 72 cycles, 30 min each Copper, Nickel plated Non-conductive FR4 (UL 94 V-0 rated) Epoxy (UL 94 V-0 rated) Copper Nickel (2 - 3 µm) Tin (3 - 5 µm), matte Metal Case PCB Mount THD (Through-Hole Device) 2" x 1" Wave Soldering 260°C / 6 s max. 27 g 12 K/W typ. 10 K/W typ. (with Heat Sink) www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) - Case to Ambient Environmental Compliance - REACH Declaration - RoHS Declaration Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/ten20win All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 4 / 5 TEN 20WIN Series, 20 Watt Outline Dimensions 15.2 (0.800) (0.60) (1.00) Dual 1 +Vin (Vcc) 2 –Vin (GND) 3 +Vout 4 10.2 20.32 5.6 5 Single Trim Common 5 –Vout 6 Remote On/Off (0.22) Bottom view 6 25.4 (0.300) 7.62 2.5 (0.10) 5.08 (0.200) 4 2 Pin (0.40) 1 (0.400) (0.400) Pinout 3 10.16 10.16 (0.300) 7.62 50.8 (2.00) Insulated baseplate Dimensions in mm (inch) Pin diameter: 1.0 ±0.1 (0.04 ±0.004) Tolerances: x.x ±0.5 (x.xx ±0.02) x.xx ±0.25 (x.xxx ±0.01) © Copyright 2022 Traco Electronic AG Specifications can be changed without notice. www.tracopower.com Rev. November 30, 2022 Page 5 / 5
TEN 20-2411WIN 价格&库存

很抱歉,暂时无法提供与“TEN 20-2411WIN”相匹配的价格&库存,您可以联系我们找货

免费人工找货
TEN 20-2411WIN
  •  国内价格
  • 1+3973.85774
  • 2+3886.43358
  • 4+3802.98750

库存:30